Multimeter PCE-DC 50 measurement of currents up to 1000 A AC/DC - PCE Instruments
MultimeterWith real effective value measurement / Measurements: current, voltage, temperature / Bluetooth interface / Rubber housing / HOLD function / Automatic shutdown / Diameter drives max. 48 mm / Different functions
The PCE-DC 50 multimeter is a device that measures currents up to 1000 A AC/DC. In addition to measuring current, the multimeter measures voltage, frequency, duty cycle, resistance, capacitors and checks continuity and diodes
- Current measurement up to 1000 A
- connection plugs with closure
- Voltage measurement up to 600 V
- Temperature measurement with 2 thermo-elements
- Bluetooth interface
DELIVERY CONTENT
1 x PCE-DC 50 Multimeter
1 x Set of test cables
1 x Carrying case
1 x Software
1 x Bluetooth Adapter
2 x Type K thermoelements
1 x 9V battery
SPECIFICATIONS
Current DC A |
Range |
Resolution |
Accuracy (of value) |
500 µA |
0.01µA |
± (1% 6 digits) |
5000 µA |
0.1µA |
± (1% 6 digits) |
50 a |
0.01A |
± (2.5% + 5 digits) |
1000 A |
0.1A |
± (2.5% 30 digits) |
|
AC current A |
Range |
Resolution |
Accuracy (of value) |
500 µA |
0.01µA |
± (1.5% + 30 digits) |
5000 µA |
0.1µA |
± (1.5% + 30 digits) |
50 a |
0.01A |
± (2.5% 30 digits) |
1000 A |
0.1A |
± (2.8% + 30 digits) |
|
Voltage: For measuring alternating current, the accuracy indicated corresponds to a measurement at 50/60 Hz and a range ranging from 5 to 100%. |
|
Resistance |
Range |
Resolution |
Accuracy (of value) |
500Ω |
0.01 |
± (1% + 9 digits) |
5 kΩ |
0.0001 |
± (1% + 5 digits) |
50kΩ |
0.001 |
± (1% + 5 digits) |
500kΩ |
0.01 |
± (1% + 5 digits) |
5 MΩ |
0.0001 |
± (3% 10 digits) |
50 MΩ |
0.001 |
± (3.5% + 10 digits) |
|
DC V voltage |
Range |
Resolution |
Accuracy (of value) |
500 mV |
0.01 mV |
± (0.1% + 8 digits) |
5V |
0.0001V |
± (0.1% + 4 digits) |
50 V |
0.001V |
± (0.1% + 4 digits) |
500 V |
0.01V |
± (0.1% + 4 digits) |
600V |
0.1V |
± (0.5% + 4 digits) |
|
AC voltage V (50 Hz ... 1000 Hz) |
Range |
Resolution |
Accuracy (of value) |
500 mV |
0.01 mV |
± (0.8% + 9 digits) (at 50 Hz / 60 Hz) |
5V |
0.0001V |
± (1% + 30 digits) |
50 V |
0.001V |
± (1% + 30 digits) |
500 V |
0.01V |
± (1% + 30 digits) |
600V |
0.1V |
± (1% + 30 digits) |
|
Note: For measuring AC voltage, the accuracy indicated corresponds to a measurement between 50 and 1000 Hz and a range ranging from 5 to 100%. |
|
Ability |
Range |
Resolution |
Accuracy (of value) |
500 nF |
0.01 |
± (3.5% + 40 digits) |
5000nF |
0,1 |
± (3.5% + 10 digits) |
50µF |
0.001 |
± (3.5% + 10 digits) |
500 µF |
0.01 |
± (3.5% + 10 digits) |
5 MF |
0.0001 |
± (5 % + 10 digits) |
|
Frequency |
Range |
Resolution |
Accuracy (of value) |
50Hz |
0.001 |
± (0.3% + 2 digits) |
500Hz |
0.01 |
± (0.3% + 2 digits) |
5kHz |
0.0001 |
± (0.3% + 2 digits) |
50kHz |
0.001 |
± (0.3% + 2 digits) |
500kHz |
0.01 |
± (0.3% + 2 digits) |
5 Mhz |
0.0001 |
± (0.3% + 2 digits) |
10 MHz |
0.001 |
± (0.3% + 2 digits) |
|
Work cycle |
Range |
Resolution |
Accuracy (of value) |
5% ... 95% |
0,1 |
± (1% + 2 digits) (of measured value)
|
|
|
|
Pulse width: 100 µs...100 ms |
|
|
Frequency: 10Hz...10kHz |
|
|
|
Temperature |
Range |
Resolution |
Accuracy (of value) |
-100 °C ... 1000 °C |
0,1 |
± (1 % + 2.5 °C) |
|
General technical specifications |
Duct diameter |
Max. 48 mm |
Screen |
Double, 50,000 digits |
Continuity test |
50 Ohm / |
Diode testing |
0.3 mA / 2.8 V DC |
Battery level |
A symbol appears when the level is low |
Overrun |
“OL” indication when the range is outdated |
Measurement share |
2Hz |
Interface |
Bluetooth |
Detection peak |
> 1 ms |
Thermo element |
Type K |
Fusible |
Ceramic fuse, 500 mA |
AC bandwidth (AC A / AC V) |
50 Hz ... 400 Hz |
AC measurement |
True RMS |
Working conditions |
5 °C ... 40 °C / max. 80 % H.r. at 31 °C |
Storage conditions |
-20 °C ... 60 °C / max. 80 per cent H.r. |
Food |
9 V |
Automatic shutdown |
After 30 minutes of inactivity |
Dimensions |
230 x 76 x 40mm |
Weight |
315 g |
Security |
IEC 1010-1(2001): EN 61010-1(2001) CAT III 600 V CAT II 1000 V Level of contamination 2 |