![Mesureur d'isolement PCE-ITE 50 - PCE Instruments Mesureur d'isolement PCE-ITE 50 - PCE Instruments](https://pros-r.com/11619-large_default/insulation-meter-pce-ite-50-pce-instruments.jpg)
Reference: PCE-IT55
Brand: PCE INSTRUMENTS
Insulation meter - PCE-IT55 - PCE Instruments
Isolation meter - PCE-IT55 - PCE Instruments Isolation meter / Measure resistance, isolation resistance and tension Warranty 1 year
€261.48 including tax
Isolation meter - PCE-ITE 50 - PCE Instruments
Isolation meter / Isolation resistance / Earth resistance / loop impedance / Voltage measurement / Low impedance measurement / RCD Test
Warranty 1 year
Insulation meter - PCE-ITE 50 - PCE Instruments
Insulation meter / Insulation resistance / Earth resistance / Loop impedance / Voltage measurement / Low impedance measurement / RCD test
The insulation meter is equipped with a large 3.5" color TFT screen. The insulation meter offers, in addition to different measurement modes: insulation resistance, earth resistance, loop impedance, voltage, measurement of low ohm values and RCD test. Thanks to the insulation meter, you will be able to check that fixed installations are placed correctly and safely. Thanks to its large screen, its intuitive symbols and its high degree of vision , you will be able to carry out an easy and quick measurement.
Thanks to the low frequency ohmmeter of the insulation tester, you can check the outlets earth, equipotential bonding bars and protective conductors for low frequency. The low impedance measurement sampling frequency of the insulation meter is 0 to 2000 Ω with a resolution of 0.001 to 1 Ω. The main use of the device is the measurement of insulation resistance. For insulation measurements, the electrical lines are tensioned to allow leakage currents to pass, which generally generate temperature. In most cases, current leaks are so small that they are usually not detected by safety devices, but in the worst case can cause a fire.
The insulation tester can measure installations with a test voltage of 125 V, 250 V, 500 V and 1000 V. The test current is generally less than or equal to 1 mA. The insulation tester is grounded independently of the power supply. To connect all the installations and circuits of an energy system to a common potential and to protect against short circuits and overvoltages, the earth resistance must have the lowest possible impedance. With a range measuring from 0 to 2000 Ω and a resolution of 0.01 to 1 Ω, the insulation tester therefore offers all the conditions for a meaningful measurement of earth resistance.
- Loop resistance LN, L-PE and N-PE
- RCD test: adjustable current
- Earth resistance measurement
- Low impedance measurement
- Voltage up to 1000 V
- 3.5" color TFT screen
- Micro SD card and Bluetooth
- Optional: ISO calibration certificate
DELIVERY CONTENT
1 x Insulation meter
1 x Strap
3 x Alligator clips
3 x Test leads with standard test point
1 x High voltage test tip
1 x Power Socket Test Cable
1 x Power Adapter
1 x Charger for cigarette lighter socket
1 x USB Bluetooth Adapter
1 x Software
8 x 1.2 V batteries, Ni-MH type
1 x Transport case
1 x User Manual
Insulation test | ||
125V (0...10%) | ||
Range | Resolution | Precision |
0.125 … 4 MΩ | 0.001 MΩ | ± (3% 10 digits) |
4.001 … 40 MΩ | 0.01 MΩ | ± (2 % + 10 digits) |
40,01 … 400 MΩ | 0.1 MΩ | ± (4% 5 digits) |
400.1 ... 1000 MΩ | 1 MΩ | ± (5% + 5 digits) |
Test current | 1 mA @ Last 125 kΩ | |
Short circuit | ≤ 1 mA | |
250 V (0 ... 10%) | ||
Range | Resolution | Precision |
0.250 … 4 MΩ | 0.001 MΩ | ± (3% 10 digits) |
4.001 … 40 MΩ | 0.01 MΩ | ± (2 % + 10 digits) |
40,01 … 400 MΩ | 0.1 MΩ | ± (3 % + 2 digits) |
400.1 ... 1000 MΩ | 1 MΩ | ± (3 % + 2 digits) |
Test current | 1 mA @ Last 250 kΩ | |
Short circuit | ≤ 1 mA | |
500 V (0 … 10%) | ||
Range | Resolution | Precision |
0.500 … 4 MΩ | 0.001 MΩ | ± (3% 10 digits) |
4.001 … 40 MΩ | 0.01 MΩ | ± (2 % + 10 digits) |
40,01 … 400 MΩ | 0.1 MΩ | ± (3 % + 2 digits) |
400.1 ... 1000 MΩ | 1 MΩ | ± (4% 5 digits) |
Test current | 1 mA @ Last 500 kΩ | |
Short circuit | ≤ 1 mA | |
1000 V (0 … 10%) | ||
Range | Resolution | Precision |
1,000 … 4 MΩ | 0.001 MΩ | ± (3% 10 digits) |
4.001 … 40 MΩ | 0.01 MΩ | ± (2 % + 10 digits) |
40,01 … 400 MΩ | 0.1 MΩ | ± (3 % + 2 digits) |
400.1 ... 1000 MΩ | 1 MΩ | ± (4% 5 digits) |
Test current | 1 mA @ Last 1 MΩ | |
Short circuit | ≤ 1 mA | |
Low impedance (Low Ohm) | ||
Range | Resolution | Precision |
0.000 … 2.000 Ω | 0.001Ω | ± (1.5% + 30 digits) |
2.00 … 20.00 Ω | 0.01Ω | ± (1.5% + 3 digits) |
20.0 … 200.0 Ω | 0.1Ω | ± (1.5% + 3 digits) |
200 … 2000 Ω | 1Ω | ± (1.5% 5 digits) |
Open circuit voltage | Max. 5.8V | |
Overload protection | 250 Vrms | |
Short circuit | ≥ 200mA | |
Continuity tester | ||
Range | Resolution | |
2000 Ohms | 0.01Ω | |
Open circuit voltage | Max. 5.8V | |
Overload protection | 250 Vrms | |
Voltage measurement | ||
Range | Resolution | Precision |
80 … 500 V AC/DC | 1V | ± (2% 2 digits) |
Frequency measurement | ||
Range | Resolution | Precision |
45 … 65 Hz | 1Hz | ±2Hz |
Loop resistance | ||
L-PE (Hi-Amp) | ||
Range | Resolution | Precision |
0.23 … 9.99 Ω | 0.01Ω | ± (4% + 4 digits) |
10.0 … 99.9 Ω | 0.1Ω | ± (4% + 4 digits) |
100 … 999 Ω | 1Ω | ± (4% + 4 digits) |
Loop current | 4A | |
Range of voltage | 195 … 260 V AC (50/60 Hz) | |
L-PE (no trigger) | ||
Range | Resolution | Precision |
0.23 … 9.99 Ω | 0.01Ω | ± (5% + 6 digits) |
10.0 … 99.9 Ω | 0.1Ω | ± (5% + 6 digits) |
100 … 999 Ω | 1Ω | ± (5% + 6 digits) |
Loop current | ||
Range of voltage | 195 … 260 V AC (50/60 Hz) | |
L-N | ||
Range | Resolution | Precision |
0.23 … 9.99 Ω | 0.01Ω | ± (4% + 4 digits) |
10.0 … 99.9 Ω | 0.1Ω | ± (4% + 4 digits) |
100 … 999 Ω | 1Ω | ± (4% + 4 digits) |
Loop current | 4A | |
Range of voltage | 195 … 260 V AC (50/60 Hz) | |
Measurement of soil resistance | ||
0.00 … 99.99 Ω | 0.01Ω | ± (2% + 30 digits) |
100.0 … 999.9 Ω | 0.1Ω | ± (2% + 6 digits) |
1000 … 2000 Ω | 1Ω | ± (2% + 6 digits) |
RCD test | ||
RCD (In) | 10mA / 30mA / 100mA / 300mA / 650mA / 1A | |
Factors | x½ / x1 / x2 / x5 | |
Accuracy over time | ± (1 % + 1m) | |
trigger | ||
Waveform | Sinus (AC) | |
of test current | Pulse (DC) | |
Characteristic of | G (instantaneous) | |
trigger | S (delayed) | |
Phase orientation | 0º or 180º | |
Input voltage | 195 … 260 V AC (50/60 Hz) | |
Accuracy of injected current | ± (5% 2 digits) | |
Other specifications | ||
Food | 8 x 1.2 V batteries, type NI-MH, or | |
8 x 1.5 V alkaline batteries, type AA | ||
Autonomy | Approximately 15 hours (for alkaline batteries) | |
Category | CAT III 600 V | |
Protection | IP65 | |
Screen | 3.5" TFT, 320 x 240 pixels | |
Operating temperature | 0 … 45ºC | |
Storage temperature | -10 … +60 ºC | |
Relative humidity | 0 … 95% H.r. without condensation | |
Operational altitude | 2000m | |
Dimensions | 24.2 x 10.5 x 14.5 cm | |
Weight | 1.56kg |
Reference: PCE-IT55
Brand: PCE INSTRUMENTS
Isolation meter - PCE-IT55 - PCE Instruments Isolation meter / Measure resistance, isolation resistance and tension Warranty 1 year
Reference: PCE-DC 50
Brand: PCE INSTRUMENTS
Multimeter PCE-DC 50 measurement of currents up to 1000 A AC/DC - PCE Instruments Multimeter with actual value measurement / Measurements: current, voltage, temperature / Bluetooth interface / Rubber housing / HOLD function / Automatic shutdown / Diameter drives max. 48 mm / Different functions Warranty 1 year
Reference: PCE-RTD 20
Brand: PCE INSTRUMENTS
RTD Calibrator - PCE-RTD 20 - Simulation of Resistances and Sensors ... - PCE Instruments RTD / Simulation and resistance measurement, Pt sensors, current and voltage / Li-Ion battery / Continuity check / rampa function Warranty 1 year
Reference: PCE-GPA 50
Brand: PCE INSTRUMENTS
Multimeter PCE-GPA 50 measures the consumption of monophasic and triasic electrical appliances - PCE Instruments Multimeter up to 2000 A / Measurement TRMS / Power measurement / Harmonic analyzer / Graphic indication with backlight / Memory / Electric network function and batteries Warranty 1 year
Reference: PCE-ERT 10
Brand: PCE INSTRUMENTS
Mobile Earth Controller - PCE-ERT 10 - PCE Instruments 3-pole method 62% Warranty 1 year
Reference: PCE-DC 20
Brand: PCE INSTRUMENTS
Pliers PCE-DC 20 - PCE Instruments AC/DC digital controller with direct frequency measurement in the clamp / LCD screen / Automatic shutdown / current measurement up to 1000 A / For mobile use / Clamp opening: 40 mm Warranty 1 year
Reference: PCE-IT414
Brand: PCE INSTRUMENTS
Insulation meter - PCE-IT414 - for high voltage up to 10000 V - PCE Instruments 1 year warranty
Reference: PCE-CTI 10
Brand: PCE INSTRUMENTS
PCE-CTI 10 Wireless current clamp - PCE Instruments TRMS current detector with Bluetooth 4.0 / Range: 0 ... 1500 V AC/DC / Extensible up to 3000 A AC with flexible current clamp / VFD mode / Start current measurement / Optional: Calibration Certificate Warranty 1 year
Isolation meter - PCE-ITE 50 - PCE Instruments
Isolation meter / Isolation resistance / Earth resistance / loop impedance / Voltage measurement / Low impedance measurement / RCD Test
Warranty 1 year