DC voltage
|
Range
|
600.0mV |
Resolution
|
0.1mV |
Precision
|
±(0.8% value + 8 digits) |
Range
|
6,000V |
Resolution
|
0.001V |
Precision
|
±(0.5% of value + 5 digits) |
Range
|
60.00V |
Resolution
|
0.01V |
Precision
|
±(0.5% of value + 5 digits) |
Range
|
600.0V |
Resolution
|
0.1V |
Precision
|
±(0.8% of value + 5 digits) |
Range
|
1500V |
Resolution
|
1V |
Precision
|
±(0.8% of value + 5 digits) |
Input impedance: >10 MΩ; Surge protection: 1500 V DC / 1000 V AC RMS
|
|
AC voltage
|
Range
|
0.000 ... 6.000 V |
Resolution
|
0.001V |
Precision
|
50 ... 60 Hz: ±(1.2% of value + 5 digits) 61 ... 1 kHz: ±(2.5% of value + 5 digits) |
Range
|
0.00 ... 60.00 V |
Resolution
|
0.01V |
Precision
|
50 ... 60 Hz: ±(1.2% of value + 5 digits) 61 ... 1 kHz: ±(2.5% of value + 5 digits) |
Range
|
0.0 ... 600.0 V |
Resolution
|
0.1V |
Precision
|
50 ... 60 Hz: ±(1.2% of value + 5 digits) 61 ... 1 kHz: ±(2.5% of value + 5 digits) |
Range
|
0 ... 1500 V |
Resolution
|
1V |
Precision
|
50 ... 60 Hz: ±(1.2% of value + 5 digits) 61 ... 1 kHz: ±(2.5% of value + 5 digits) |
Accuracy is applicable between 10 and 100% of the range respective measurement and a sine wave. Input impedance: >9 MΩ; Surge protection: 1000 V AC/DC RMS The accuracy of the "PEAK" function is ±10% of the value The response time of the "PEAK" function is 1 ms.
|
|
AC voltage with low input impedance (LowZ)
|
Range
|
0.000 ... 6.000 V |
Resolution
|
0.001V |
Precision
|
±(3.0% of value + 40 digits) |
Range
|
0.00 ... 60.00 V |
Resolution
|
0.01V |
Precision
|
±(3.0% of value + 40 digits) |
Range
|
0.0 ... 300.0 V |
Resolution
|
0.1V |
Precision
|
±(3.0% of value + 40 digits) |
Input impedance: 300 kΩ; Surge protection: 1000 V DC / V AC RMS Accuracy is applicable between 10 and 100% of the range respective measurement and a sine wave
|
|
DC and AC voltages (50 ... 1 kHz)
|
Range
|
0.000 ... 6.000 V |
Resolution
|
0.001V |
Precision
|
±(2.5% of value + 40 digits) |
Range
|
0.00 ... 60.00 V |
Resolution
|
0.01V |
Precision
|
±(2.5% of value + 40 digits) |
Range
|
0.0 ... 600.0 V |
Resolution
|
0.1V |
Precision
|
±(2.5% of value + 40 digits) |
Range
|
0 ... 1000 V |
Resolution
|
1V |
Precision
|
±(2.5% of value + 40 digits) |
Input impedance: 300 kΩ; Surge protection: 1000 V DC / V AC RMS
|
|
DC and AC voltages with low input impedance (LowZ)
|
Range
|
0.000 ... 6.000 V |
Resolution
|
0.001V |
Precision
|
±(3.5 % of value + 40 digits) |
Range
|
0.00 ... 60.00 V |
Resolution
|
0.01V |
Precision
|
±(3.5 % of value + 40 digits) |
Range
|
0.0 ... 300.0 V |
Resolution
|
0.1V |
Precision
|
±(3.5 % of value + 40 digits) |
Input impedance: 300 kΩ; Surge protection: 1000 V DC / V AC RMS
|
|
Non-contact voltage detector (NCV)
|
Range
|
100 ... 1000 AC/DC |
|
Direct current
|
|
Range
|
60.00 A |
Resolution
|
0.01A |
Precision
|
±(3.0% of value + 8 digits) |
Range
|
600.0 A |
Resolution
|
0.1A |
Precision
|
±(3.0% of value + 8 digits) |
Range
|
1000 A |
Resolution
|
1A |
Precision
|
±(3.0% of value + 8 digits) |
Surge protection: 1000 A AC/DC
|
|
Direct current (50 ... 60 Hz)
|
Range
|
0.00 ... 60,00 A |
Resolution
|
0.01A |
Precision
|
±(2.5% of value + 5 digits) |
Range
|
0.0 ... 600.0 A |
Resolution
|
0.1A |
Precision
|
±(2.5 % of value + 5 digits) |
Range
|
0 ... 1000 A |
Resolution
|
1A |
Precision
|
±(2.5 % of value + 5 digits) |
Surge protection: 1000 A AC/DC Accuracy is applicable between 10 and 100% of the range respective measurement and a sine wave. The starting current is only indicative.
|
|
Alternating current with optional current clamp (PCE-DM-CLAMP)
|
Range
|
0.00 ... 30.00 A |
Resolution
|
0.01A |
Precision
|
±(3.0% of value + 5 digits) |
Range
|
0.0 ... 300.0 A |
Resolution
|
0.1A |
Precision
|
±(3.0% of value + 5 digits) |
Range
|
0 ... 3000 A |
Resolution
|
1A |
Precision
|
±(3.0% of value + 5 digits) |
Range frequency
|
50...400Hz |
Opening diameter
|
Ø457 mm / Ø18" |
Surge protection: 1000 A AC/DC Accuracy is applicable between 10 and 100% of the range respective measurement and a sine wave
|
|
Resistance and continuity test
|
Range
|
0.0 ... 600.0 Ω |
Resolution
|
0.1Ω |
Precision
|
±(1.0% of value + 10 digits) |
Range
|
0.000 ... 6,000 kΩ |
Resolution
|
0.001 kΩ |
Precision
|
±(0.8% value + 5 digits) |
Range
|
0.00 ... 60,00 kΩ |
Resolution
|
0.01kΩ |
Precision
|
±(0.8% of value + 5 digits) |
Range
|
0.0 ... 600.0 kΩ |
Resolution
|
0.1kΩ |
Precision
|
±(0.8% of value + 5 digits) |
Range
|
0.000 ... 6.000 MΩ |
Resolution
|
0.001 MΩ |
Precision
|
±(0.8% of value + 5 digits) |
Range
|
0.00 ... 60.00 MΩ |
Resolution
|
0.01 MΩ |
Precision
|
±(2.5 % of value + 10 digits) |
Audible signal during continuity test:
Surge protection: 1000 A AC/DC
|
|
Frequency
|
Range
|
0.00 ... 60,00 Hz |
Resolution
|
0.01Hz |
Precision
|
±(0.2% of value + 5 digits) |
Range
|
0.0 ... 600.0 Hz |
Resolution
|
0.1Hz |
Precision
|
±(0.2% of value + 5 digits) |
Range
|
0.000 ... 6,000 kHz |
Resolution
|
0.001 kHz |
Precision
|
±(0.2% of value + 5 digits) |
Range
|
0.00 ... 60.00 kHz |
Resolution
|
0.01kHz |
Precision
|
±(0.2% of value + 5 digits) |
Range
|
0.0 ... 600.0 kHz |
Resolution
|
0.1kHz |
Precision
|
±(0.2% of value + 5 digits) |
Range
|
0.000 ... 6.000 MHz |
Resolution
|
0.001 MHz |
Precision
|
±(0.2% of value + 5 digits) |
Surge protection: 1000 A AC/DC Sensitivity: >2 Vrms with a duty cycle between 20 ... 80% and a frequency
>5 Vrms with a duty cycle between 20 ... 80% and a frequency >100 kHz
|
|
Duty cycle
|
Range
|
10.0...90.0% |
Resolution
|
0.1% |
Precision
|
±(1.2% of value + 8 digits) |
Range frequency: 40 ... 10 kHz; Pulse amplitude ±5 V with duration between 100 µs and 100 mS
|
|
Ability
|
Precision
|
0.00...60.00nF |
Range
|
0.01nF |
Resolution
|
±(3.0% of value + 20 digits) |
Precision
|
0.0...600.0nF |
Range
|
0.1nF |
Resolution
|
±(3.0% of value + 8 digits) |
Precision
|
0.000 ... 6.000 µF |
Range
|
0.001µF |
Resolution
|
±(3.0% of value + 8 digits) |
Precision
|
0.00 ... 60.00 µF |
Range
|
0.01µF |
Resolution
|
±(3.0% of value + 8 digits) |
Precision
|
0.0...600.0nF |
Range
|
0.1nF |
Resolution
|
±(3.0% of value + 8 digits) |
Precision
|
0 ... 6000 µF |
Range
|
1µF |
Resolution
|
±(3.5% of value + 20 digits) |
Precision
|
0.00 ... 60.00 mF |
Range
|
0.01mF |
Resolution
|
only indicative |
Precision
|
0.0 ... 600.0mF |
Range
|
0.1mF |
Resolution
|
only indicative |
Surge protection: 1000 A AC/DC
|
|
Temperature with type K thermoelement
|
Range
|
-40.0 ... 600.0 °C |
Resolution
|
0.1°C |
Precision
|
±(1.5% of value + 3°C) |
Range
|
600 ... 1000 °C |
Resolution
|
1°C |
Precision
|
±(1.5% of value + 3°C) |
Range
|
-40.0...600.0°F |
Resolution
|
0.1°F |
Precision
|
±(1.5% of value + 5.4°F) |
Range
|
600...1800°F |
Resolution
|
1°F |
Precision
|
±(1.5% of value + 5.4°F) |
Range
|
245.0...600.0K |
Resolution
|
0,1 K |
Precision
|
±(1.5% of value + 3 K) |
Range
|
600...1273K |
Resolution
|
1K |
Precision
|
±(1.5% of value + 3 K) |
Surge protection: 1000 A AC/DC
|
|
Diode testing
|
Test current
|
|
Maximum voltage
|
3,3 V DC |
|
Other specifications
|
Memory
|
16 groups, total memory of 100,000 values |
Horizontal clamp diameter
|
38mm |
Vertical clamp diameter
|
63 mm |
Clamp opening
|
45mm |
Protection
|
IP65 |
Interface
|
Bluetooth 4.0 |
Degree of contamination
|
2 |
Category
|
CAT IV 600 V, CAT III 1000 V, CAT II 1500 V |
Maximum operating altitude
|
2000 m / 6562 ft |
Battery
|
Lithium, 7.4V, 1200mAh |
Charger power supply
|
Input Output |
100 ... 240 V AC, 50 ... 60 Hz 12 V DC, 2 A |
Charger plug type
|
Europe, USA, England, China |
Battery status indication
|
Yes |
Automatic shutdown
|
Off, 15, 30 or 60 minutes |
Screen
|
2.36" TFT |
Update on screen
|
3Hz |
Reference conditions
|
18...28°C / 64...82°F;
|
Working conditions
|
5...40°C / 41...104°F
|
Storage conditions
|
-20...60°C / -4...140°F
|
Dimensions
|
275 x 100 x 45mm |
Weight
|
481g
|