PCE-DC 20 current clamp - PCE Instruments
Digital AC/DC controller with direct frequency measurement in the clamp / LCD display / Automatic shutdown / Current measurement up to 1000 A / For mobile use / Clamp opening: 40 mm
The digital AC/DC controller is a multifunction device that determines current, voltage and many other electrical parameters. The opening of the digital controller clamp is 40 mm, which allows measuring in cables and lines with a larger diameter. Thanks to this, it is possible to measure currents up to 1000 A AC/DC.
Unlike other conventional digital controller, user can use this AC/DC digital controller to measure frequencies. This is why it is a valuable tool for all electricians.
- Clamp opening: 40 mm
- Backlit LCD screen
- Automatic shutdown
- As soon as it is started, it is ready to measure
- Different measuring functions
- Automatic selection of range
DELIVERY CONTENT
1 x AC/DC digital controller
1 x Measuring cables
3 x 1.5 V AAA type batteries
1 x Carrying bag
1 x User Manual
SPECIFICATIONS
DC current |
Range measuring
|
Resolution
|
Precision
|
400 A
|
0.1A
|
±3% + 5 digits
|
600 A
|
1A
|
±3% + 5 digits
|
1000 A
|
1A
|
±3% + 6 digits
|
|
Overvoltage protection: 120% of range measurement for a maximum of 60 seconds.
|
|
AC current |
Range measuring
|
Resolution
|
Precision
|
400 A
|
0.1A
|
±3% + 5 digits
|
600 A
|
1A
|
±3% + 5 digits
|
1000 A
|
1A
|
±3% + 6 digits
|
|
Range frequency: 50 ... 60 Hz Overvoltage protection: 120% of range measurement for a maximum of 60 seconds.
|
|
DC voltage |
Range measuring
|
Resolution
|
Precision
|
4V
|
1mV
|
±0.5% 5 digits
|
40V
|
10mV
|
±0.5% 5 digits
|
400V
|
0.1V
|
±0.5% 5 digits
|
600V
|
1V
|
±1% + 5 digits
|
1000V
|
1V
|
±1% + 5 digits
|
|
Input Impedance: 10MΩ Surge protection: 1000 VDC or 700 VAC RMS
|
|
AC voltage |
Range measuring
|
Resolution
|
Precision
|
4V
|
1mV
|
±1.2% + 5 digits
|
40V
|
10mV
|
±1.2% + 5 digits
|
400V
|
0.1V
|
±1.2% + 5 digits
|
600V
|
1V
|
±2% + 5 digits
|
1000V
|
1V
|
±2% + 5 digits
|
|
Input Impedance: 10MΩ Surge protection: 1000 VDC or 700 VAC RMS Range frequency: 40 ... 400 Hz
|
|
Resistance |
Range measuring
|
Resolution
|
Precision
|
400Ω
|
0.1Ω
|
±1% + 5 digits
|
4kΩ
|
1Ω
|
±1% + 5 digits
|
40kΩ
|
10Ω
|
±1% + 5 digits
|
400kΩ
|
0.1kΩ
|
±1% + 5 digits
|
4 MΩ
|
1kΩ
|
±1% + 5 digits
|
40 MΩ
|
10kΩ
|
±2% + 5 digits
|
|
Overvoltage protection: 250 V AC/DC RMS
|
|
Frequency (direct) |
Range measuring
|
Resolution
|
Precision
|
40Hz
|
1Hz
|
±0.1% 1 digit
|
400Hz
|
1Hz
|
±0.1% 1 digit
|
4kHz
|
10Hz
|
±0.1% 1 digit
|
40kHz
|
100Hz
|
±0.1% 1 digit
|
100kHz
|
100Hz
|
±0.1% 1 digit
|
|
Range measurement: 1 ... 10 V RMS, 40 Hz ... 100 kHz
|
|
Frequency |
Range measuring
|
Resolution
|
Precision
|
40Hz
|
0.01Hz
|
±0.1% 1 digit
|
400 Hz (clamp current)
|
0.1Hz
|
±0.1% 1 digit
|
|
Range frequency: 40 ... 400 Hz (>20 A)
|
|
Other measurement functions
|
Continuity test
|
Audible signal if |
Diode testing
|
Indicates forward voltage
|
|
Other specifications
|
Measurement share
|
2 ... 3 measurements per second
|
Screen
|
3999 digit LCD
|
Selection of range
|
Automatic
|
Automatic shutdown
|
After 30 minutes of inactivity, can be deactivated
|
Maximum clamp opening
|
40mm
|
Coefficient
|
0.1 x precision x °C*
|
Maximum voltage
|
1000 V CAT II, 600 V CAT III
|
Maximum operating altitude
|
2000 m above sea level
|
Working conditions
|
5 ... 35 °C, |
Storage conditions
|
-10 ... 35 °C, |
Food
|
3 x 1.5 V AAA type batteries
|
Dimensions
|
225 x 86 x 32mm
|
Weight
|
About 330g
|
The accuracies shown refer to ambient conditions between 18 and 28°C, and between 65 and 83°F.
* The temperature is the result of the difference between the temperature of the operating conditions and the current ambient temperature.
Example: When the current ambient temperature is higher than the operating temperature (50ºC [température ambiante actuelle] - 40ºC [température de fonctionnement]) = 10ºC
When the current ambient temperature is lower than the operating temperature (0ºC [température ambiante actuelle] - 5ºC [température de fonctionnement]) = 5ºC
|