Communication & monitoring |
Communication interfaces |
MasterBus, CZone, NMEA |
|
General specifications |
Rated output voltage |
24 V |
Max. output current for primary output |
60A |
Smart In-/Output output voltages |
12 or 24 V |
Smart In-/Output output current |
5-10 A to 12 V; 5-20 A to 24 V (adjustable) |
Smart In-/Output input current |
max. 20 A to 24 V |
Total charge current |
60 A at 28.8 V |
Maximum AC current |
10.2A / 20.4A |
Number of battery outputs |
3 (max.) |
Battery capacity range |
200-500 Ah |
Rated input voltage |
120/230V (80-275V) 50/60Hz |
Connexion AC |
screw terminal block for cables up to 6 mm² |
Powers your system without battery |
yes |
Galvanic isolation |
yes |
Display/indicator |
lED display |
Dimensions, HxWxD |
384 x 250 x 127mm 15.1 x 9.8 x 5.0 inches |
Weight |
5.9 kg 13.0 pounds |
Standards |
CE, Aby, UL1236, SAE J1171, ISO 8846, CEC/DOE, RCM/C-Tick, RMRS, RRR |
|
Technical specifications |
Load characteristics |
IUoUo, automatic / 3-steps+ for Gel/AGM/Lithium Ion/traction/spiral |
Temperature compensation |
-60 mV/°C / -76 mV/°F; temperature sensor included |
DC voltage compensation |
by automatic compensation or MasterShunt |
Power consumption (DC side) |
|
Current Control function |
yes, via MasterBus or CZone |
Power factor control |
> 0.98 |
Temperature range (ambient temp) |
-25°C to 80°C, decreasing 40°C -13°F to 176°F |
Cooling |
vario fan |
Protection sign |
IP23, vertical mounting |
Protections |
overheating, overcharging, short circuit, high/low battery voltage, ignition protection |
MasterBus compatible |
yes |
Charger status interface (alarm contact) |
yes, using a Multifunction Contact Output (ref. 77030500) |