Convertisseur sinusoïdal AC Master 24V/300W IEC - 230V - Mastervolt
Reliable AC power supply for leisure and semi-professional use
With a compact, light and silent AC Master you can easily convert the voltage of a 12 or 24 V battery to 230 V/50 Hz CA. The pure sinusoidal output preserves equipment without cutting, buzzing or line on your screens, while ensuring a longer lifespan for all connected devices and saving the costs of all adapters.
Features :
Universal socket
Designed for leisure and semi-professional applications
Specificities :
Output voltage: 230 V - 50 Hz (± 0.1%)
Nominal battery voltage: 24 V
Recommended battery capacity : ≡ 30 Ah
Continuous power at 40°C: 250 W
Protection: IP21 - overheating, overload, short circuit, high/low battery voltage, reverse polarity (fuse)
Dimensions: 210 x 130 x 60 mm
Weight : 1.16 kg
Applications
Leisure and semi-professional uses where mains power is irregular or non-existent. Applications include lighting, cooktops and power tools. For (mobile) applications at home, in the office, in a work or leisure vehicle, or during vacation.
Specifications
|
General specifications |
Output voltage |
230 V - 50 Hz (± 0.1%) |
Output wave |
pure sinus |
Rated battery voltage |
24 V |
Recommended battery capacity |
≥ 30 Ah |
Continuous power at 25 ° C / 77 ° F, COS PHI 1 |
300W |
Continuous power at 40 °C / 104 °F, cos phi 1 |
250W |
Peak power (5 s) |
600W |
Connexion AC |
universal |
Galvanic isolation |
yes |
Yield |
91% |
Display/indicator |
lED display |
Alarms |
4 alarm modes |
Dimensions, HxWxD |
210 x 130 x 60mm 8.3 x 5.1 x 2.4 inches |
Weight |
1,16 kg 2.6 pounds |
Standards |
CE, E-mark, ABYC A-31 |
|
Technical specifications |
Technology |
high frequency, input and output perfectly isolated |
Low battery voltage, shutdown at |
20V, ±0.5V |
Low battery voltage, starts at |
22 V, ± 0.5 V |
Battery voltage high, shutdown at |
32 V, ± 0.5 V |
High battery voltage, start at |
29V, ±0.5V |
Maximum ripple on DC (battery) |
10% RMS |
Input Current (Rated Load) |
11A |
No-load power consumption (ON mode) |
0.29A – 7W |
No-load power consumption (energy saving mode) |
0,16 A - 4 W |
Minimum DC fuse (slow blow) |
40 A |
Minimum cable section |
1.5 m DC cable supplied with standard |
Typical harmonic distortion |
|
Cos phi |
all permitted power factors |
Temperature range (ambient temp) |
-20°C to 40°C, decreasing > 40°C -4 °F at 104 °F |
Cooling |
natural/forced |
Shutdown at (automatically recovered after cooling) |
50°C 122°F |
Protection sign |
IP23, vertical wall mounting |
Protections |
overheating, overcharging, short circuit, high/low battery voltage |
MasterBus compatible |
no |