Mass Sine Inverter 24V / 5000W - 230V / 50Hz - Mastervolt
Mass battery converters are designed for intensive professional use and semi-professional and sports environments. Even in the most extreme conditions, Mass series products perform flawlessly, running 24 hours a day if necessary.
The technology and reliability of the Mass concept have been tested on the ground for a long time.
You can always count on highly reliable and technologically efficient components.
Specificities
Output voltage: 230 V - 50 Hz
Nominal battery voltage: 24 V
Minimum battery capacity : ≡ 200 Ah
Continuous power at 40°C: 4000 W
Protection: IP23 - overheating, overload, short circuit, high/low voltage
Masterbus compatible
Dimensions: 470 x 315 x 254 mm
Weight 19 kg
Specifications
|
General specifications |
Output voltage (±5%) |
230 V – 50 Hz (± 0.01 Hz) |
Output wave |
pure sinus |
Rated battery voltage |
24 V |
Recommended battery capacity |
> 400 Ah |
Continuous power at 40 °C / 104 °F, cos phi 1 |
4000W |
Power P30 to 40 °C, cos phi 1 |
5000W |
Crest power |
9000W |
Connexion AC |
internal |
Galvanic isolation |
yes |
Yield |
92% |
Display/indicator |
lED display |
Dimensions, HxWxD |
470 x 315 x 254mm 18.5 x 12.4 x 10.0 inches |
Weight |
19kg 41.9 pounds |
Standards |
CE, E-mark, ABYC A-31 |
|
Technical specifications |
Technology |
Switching HF |
Low battery voltage, shutdown at |
19 V, ± 0.5 V |
Low battery voltage, starts at |
22 V, ± 0.5 V |
Battery voltage high, shutdown at |
32 V, ± 0.5 V |
High battery voltage, start at |
30 V, ± 0.5 V |
Maximum ripple on DC (battery) |
5% RMS |
Input Current (Rated Load) |
230 A |
No-load power consumption (ON mode) |
250mA – 6W |
No-load power consumption (energy saving mode) |
50mA - 1.2W |
Minimum DC fuse (slow blow) |
1x 250 A or 2x 125 A |
Minimum cable section |
2x 70 mm² |
Typical harmonic distortion |
|
Cos phi |
all permitted power factors |
Switching system |
the Masterswitch and Systemswitch can be connected to all converters |
Temperature range (ambient temp) |
-25°C to 80°C, decreasing > 40°C -13°F to 176°F |
Cooling |
natural/forced |
Protection sign |
IP23 |
Protections |
overheating, overcharging, short circuit, high/low battery voltage |
MasterBus compatible |
yes, using a MasterBus Interface Converter or an AC Power Analyzer |