AC Master sine wave converter 12V / 700W - 230V - Mastervolt
With a compact, lightweight and quiet AC Master you can easily convert the voltage of a 12 or 24 V battery into 230 V/50 Hz AC. Pure sine wave output preserves equipment without dropouts, buzzing or lines on your displays, while ensuring a longer lifespan for all connected devices and saving the costs of all adapters.
Features :
Universal socket
Designed for recreational and semi-professional applications
Specificities :
Output voltage: 230 V - 50 Hz
Rated battery voltage: 12V
Recommended battery capacity: > 100 Ah
Continuous power at 40°C: 400 W
Protection: IP21 - overheating, overload, short circuit, high/low battery voltage, reverse polarity (fuse)
Dimensions: 210 x 130 x 60 mm
Weight : 1.22 kg
Application
Leisure and semi-professional uses where mains power is irregular or non-existent. Applications include lighting, cooktops and power tools. For (mobile) applications at home, in the office, in a work or leisure vehicle, or during vacation.
Specifications
|
General specifications |
Output voltage |
200/220/230/240 V – 50/60 Hz (selectable) |
Output wave |
pure sinus |
Rated battery voltage |
12 V |
Recommended battery capacity |
≥100 Ah |
Continuous power at 25 ° C / 77 ° F, COS PHI 1 |
700W |
Continuous power at 40 °C / 104 °F, cos phi 1 |
700W |
Peak power (1 min.) |
|
Peak power (1 s) |
|
Connexion AC |
eU plug (Schuko), with UK plug (ref. 28210700) or with NZ/AU plug (ref. 28410700) |
Galvanic isolation |
yes |
Yield |
91% |
Display/indicator |
lED indicators: battery voltage, status and charge level |
Alarms |
dry contact for alarm |
Dimensions, HxWxD |
200 x 330 x 83mm 7.9 x 13.0 x 3.3 inches |
Weight |
2.7kg 6.0 pounds |
Standards |
CE, E-mark, RCM |
|
Technical specifications |
Technology |
high frequency, input and output perfectly isolated |
Low battery voltage, shutdown at |
10.5V |
Low battery voltage, starts at |
12.5V |
Battery voltage high, shutdown at |
16.5V |
High battery voltage, start at |
14.5V |
Input Current (Rated Load) |
70A |
No-load power consumption (ON mode) |
|
No-load power consumption (energy saving mode) |
|
Minimum DC fuse (slow blow) |
100A |
Minimum cable section |
25 mm² |
Typical harmonic distortion |
|
Cos phi |
all permitted power factors |
Temperature range (ambient temp) |
-20°C to 60°C, decreasing > 40°C -4°F to 140°F |
Cooling |
fan temperature and controlled load |
Protection sign |
IP21, horizontal wall mounting |
Protections |
overheating, overload, short circuit, high/low battery voltage, reverse polarity (fuse) |
MasterBus compatible |