Sinusoidal converter AC Master 12V / 300W IEC - 230V - Mastervolt
Reliable AC power supply for leisure and semi-professional use
With a compact, lightweight and quiet AC Master you can easily convert the voltage of a 12 or 24 V battery to 230 V/50 Hz CA. The pure sinusoidal output preserves the equipment without cutting, ringing or line on your screens, while ensuring a longer lifetime for all connected devices and saving the costs of all adapters.
Characteristics :
Universal Take
Designed for recreational and semi-professional applications
Marine and mobile applications, EC and E-mark standards
Specificities:
Output voltage: 200/220/230/240 V – 50/60 Hz (selected)
Rated battery voltage: 24 V
Recommended battery capacity: > 50 Ah
Continuous power at 40°C: 700 W
Protection: IP21 - horizontal mounting on partition
Masterbus compatible using a MasterBus AC Master Interface
Dimensions: 200 x 300 x 83 mm
Weight : 2.7 kg
Specifications
|
General specifications |
Output voltage |
230 V - 50 Hz (± 0.1%) |
Wave exit |
pure sinus |
Nominal battery voltage |
12 V |
Recommended battery capacity |
≥ 60 Ah |
Continuous power at 25 °C / 77 °F, cos phi 1 |
300 W |
Continuous power at 40 °C / 104 °F, cos phi 1 |
250 W |
Peak power (5 s) |
600 W |
AC connection |
universal |
Galvanic insulation |
yes |
Performance |
90 % |
Display/indicator |
lED display |
Alarms |
4 alarm modes |
Dimensions, HxlxP |
210 x 130 x 60 mm 8.3 x 5.1 x 2.4 inches |
Weight |
1.16 kg 2.6 pounds |
Standards |
EC, E-mark, ABYC A-31 |
|
Technical specifications |
Technology |
high frequency, fully insulated input and output |
Low battery voltage, shutdown at |
10 V, ± 0.5 V |
Low battery voltage, starts at |
11 V, ± 0.5 V |
High battery voltage, shutdown at |
16 V, ± 0.5 V |
High battery voltage, starts at |
14.5 V, ± 0.5 V |
Maximum undulation on DC (battery) |
10 % RMS |
Input intensity (nominal load) |
22.5 A |
Unladen power consumption (ON mode) |
0.58 A - 7 W |
Power consumption (energy saving mode) |
0.33 A - 4 W |
Minimal slow flow DC |
2x 40 A |
Minimum cable section |
1.5 m DC cable delivered as standard |
Typical harmonic distortion |
|
Cos phi |
all authorized power factors |
Temperature range (ambient temperature) |
-20 °C to 40 °C, decreasing > 40 °C -4 °F to 104 °F |
Cooling |
natural/forced |
Stopping (recovered automatically after cooling) |
50 °C 122 °F |
Protection index |
IP23, vertical mounting on partition |
Protection |
overheating, overloading, short circuit, low/high battery voltage |
Compatible MasterBus |
no |