Generator KS-6000iE-S-ATS - 5.5 kW - INVERTER - Single-phase 230V - Integrated ATS - Auto Start - Könner & Söhnen
The generator inverter KS 6000iES ATS has an integrated ATS unit and can operate in manual and automatic mode.
The OFF-RUN rotary switch on the right side of the generator combine the fuel valve, the 12 V internal power switch and the ignition switch. When generator is not used, it must remain in OFF position to prevent the lithium battery from generator don't unload. The generator comes with a disconnected battery, which must be connected under the left hood before the first use. The battery is charged from the internal charge module, during the operation of the generator, or when there is a voltage of 230 V at the sector input (NOT INPUT) (whether the rotary switch position).
The voltage on the sector input (IDS) 230V is monitored as soon as the rotary switch is in the RUN position and the ATS SWITCH is in the ON position. If the 230 V voltage at the sector input disappears, the ATS controller starts the generator and switches outlets 230 V on the power supply from the inverter module of generator.
The KS 6000iES ATS has an EWC 230V 32A socket, which is connected differently according to the version of the generator.
Only for individual electricity consumers (electrical devices)
The EWC 230V 32A is active both when the voltage is present on the sector input and when the generator is started automatically.
When you work from the sector input, the EWC 230V 32A has the same system (IT, TN, TT) that arrives in the sector input. The generator must be placed on the ground in TT and TN systems using a 6-10 mm2 copper cable (according to local regulations) by connecting its earthening screw to the same earth bus as that where the power source MAINS INPUT 230V is placed on the ground. The PE socket protection contact is linked to the landing bolt generator.
The EWC 230V 32A has an IT schema with the neutral insulated driver after switching on from the generator. It is necessary to respect the rules and measures of protection of the IT system.
Thanks to this version of generator, it is possible to provide only a direct emergency power supply to electricity consumers that can operate in both TN and IT modes. Food the whole house in automatic mode is impossible!
If you want to automatically power individual electricity consumers or their groups (house, office, etc.) in a TN system with a ground-based neutral driver, we recommend that you use the generator ATS KS 6000iE S ATS version 2.
CLAUSE OF NON-RESPONSABILITY:
This information material is intended to familiarize itself with the functions of generator and the possibilities of its application, it can only be considered as recommendations that must be adapted to the circumstances and conditions during the installation. The facility itself must be carried out by qualified personnel in accordance with all installation standards and regulations in force in the city. We are not responsible for incorrect installations and their consequences
PURE
The integrated microprocessor controlled electronic unit ensures the operating control of the generator and provides a stable output voltage of sinusoidal waveform 230V 50Hz, suitable for the reliable operation of sensitive electronics.
MOTEUR FABLE
The K engine&S reliable is characterized by increased durability, long and stable operation and meets all European quality standards, including EURO V.
ECONOMIC MODE
The ECONOMIC MODE reduces fuel consumption to 50% at low loads by slowing down the engine's speed.
INTEGRATED AUTOMATIC TRANSFER SYSTEM (ATS)
The generator is equipped with an automatic reserve inlet function. The built-in automation unit allows the generator to control the power supply of the external network and automatically lights up in case of disconnection, then automatically switches off when the current returns without user intervention.
ERGONOMICAL COMMANDE PANNEAU
The ergonomic control panel is equipped with an LED screen, a fuel saving mode switch, and a RESET button to reset the system (when the circuit breaker is triggered) and restore power supply. Control of all key operating indicators: overload protection, automatic shutdown in case of oil level too low
FAIBLE BRUIT
The soundproof protective case provides a minimum sound level (70 dB Lpa 7m), comfortable use and convenient transport.
HIGH QUALITY ALTERNATEUR
Könner wave generators & Söhnen is equipped with a high quality broom alternator with 100% copper winding. The robust and compact alternator mounted on permanent magnets, in a plastic case and capable of supporting maximum loads without damage, ensures reliable and sustainable operation of the generator.
TRANSPORT KIT
Könner wave generators & Söhnen is equipped with a transport system to facilitate travel. Two wheels and a handle that rises when moving the generator, ensure comfortable transport and mobility of the unit
Data sheet:
Only for consumers individual electric power (electrical appliances)
Tension |
230 V |
Maximum power kW |
5.5 |
Rated power kW |
5 |
Frequency |
50 hz |
Max |
23.9 A |
Outlets |
1 x EWC 230V 32A |
Start-up type |
Manual/Electric/Automatic |
Fuel tank capacity |
11 litres |
Operating time * 50% charge*** |
- |
LED display |
Time counter, frequency, voltage |
Sound level at 7 meters in dB |
70/95 |
Output 12V, A |
- |
USB output |
- |
Engine model |
KS 240i |
Engine type |
Gasoline 4 times |
Engine power, ch. |
7.5 |
Possibility of connecting generators in parallel |
- |
Exit ATS |
Integrated Automatic Transfer System |
Volume of oil crankcase |
0.70 litre |
A-h battery |
1.6 |
Protection class |
- |
Alternator winding |
Copper |
INVERTER |
- |
Weight net in kg |
40 |
Weight gross kg |
43.4 |
Net dimensions LxlXH mm |
- |
Gross dimensions LxlXH mm |
640x425x600 |