SM-01302BM

Tank 50 L - 2.7 L/h - Kholer Engine - Water cooling - Dimensions 1300x700x1000 - 413 kg

Super soundproof model 75dB(A)±3 at 7 meters - Automatic control panel without source inverter: Control device for generator with automatic start in case of power outage

Warranty 1 year

Reference : SM-01302BM

local_shipping On order +/- 10 weeks

Get it delivered everywhere in the world

€6,501.00 VAT excluded
i.e. €7,801.20 including tax
Quantity

Description

Generator soundproof FE12000-ST-KW- Fuel - Three-phase 400V 11.7 kVA (9 kW) 75 dB(A) - Electrical start - FERBO

Water cooling

Super soundproof model 75dB(A)±3 at 7 meters:

Motor coupling / Mono alternator Motor coupling/alternator in single holder with disc joint, on electrically welded steel base with anti-vibrant interposition.

Two-part soundproof box made of 20/10 sheet metal, soundproofing material of class 1, inner exhaust, manoeels and hinges, loading of fuel from the outside, mobile coupling hook, industrial paint.

Automatic control panel without source inverter:

Control device for generator with automatic start in case of power outage: Possibility of excluding network control, for manual groups and/or with remote contact start, OFF / MAN / AUTO / TEST functions, monitoring, control and protection of the motor, generator, network, inverters, reading of electrical parameters network (voltage), generator (voltage, current, power, CosPhi), engine data (battery voltage, D+, values of sensors or ECU, tachometer, hourly meter), 8 digital outputs, 8 + 1 digital inputs, 3 analog inputs, 3 password levels, flexible history with recording up to 150 events, embedded USB, 1 location available for extension and communication modules, remote control and monitoring.

TECHNICAL DONNECTIONS
Performance of the 50 Hz group
PRP 10.6 KVA
LTP 11.7 kVA
Power factor 0.8
PRP 8.48 kW
LTP 9.36 kW
Tension 400V / 230V
PRP - Prime Power : It is defined as the maximum power a generator is able to supply continuously while feeding a variable electric charge variable electric charge, when it is operated for an unlimited number of hours per year under agreed operating conditions and when intervals and maintenance procedures are respected as prescribed by the manufacturer. are carried out in accordance with the manufacturer's requirements. The average permissible power over 24 hours of operation shall not exceed 70 per cent of the starting power. A An overload capacity of 10% is available for a period of one hour during a 12-hour operating period.
LTP - Limited-Time running Power : This is the maximum available power, under agreed operating conditions, that the generator is capable of providing for 500 hours. 500 hours of operation per year (not more than 300 for continuous use) with the intervals and maintenance procedures prescribed by the manufacturers. maintenance as prescribed by manufacturers. No overload capacity is available.
Engine
Builder and model KHOLER KDW 702
Tower controller mechanical
Pb startup battery 12V 55Ah
Emission level No issue
Max power. 15 Hp
N. Tours/min 3000
Number of cylinders 2
Cylinder 686 cc
75% consumption 2.7 L/h
Alternator
Builder and model LINZ E1E11MAS or equivalent
Synchronous with capacitor regulation ± 4%
Number of poles 2
Heating class H
class insulation stator/rotor H
Degree of protection IP21
Continuous power 11.5 kVA
Soundproof model
Model cover T43
dB at 7 metres 75 dB (A) ±3
Integrated fuel tank 50 l
Dimension mm 1300x700x1000
Weight kg 413
Automatic control panel without source inverter
Magnetic circuit breaker 16 A
Taken EEC 16A 400V 5P
Control panel without source inverter COMAP IL4 AMF 9
Automatic battery charger 2.5 A
Connection for source inverter Standard
Emergency stop button Standard
Product Details
SM-01302BM

Data sheet

Starting system
ELECTRIC
Fuel
DIESEL
Tension
THREE-PHASE 400V
Version
Without AVR/INVERTER
Version
COMPATIBLE ATS
Free delivery
yes
Rated power kW
9 kW to 10.9 kW
AVAILABILITY
On order +/- 10 weeks
Rated power kVA
Above 11 kVA
ATS
TTY compatible
Attachments
Download
SM-01302BM FE12000-ST-KW

SM-01302BM FE12000-ST-KW TECHNICAL DATA SHEET FR-EN

Download (1.01MB)
8 other products in the same category:

Reference: IME-2V0000054.3

Brand: IMER FRANCE

Generator MASTER 6010 DTXL15 YN AVR+DE+DIFF Fuel Single-phase 230 V 5.2 kW - Very long range - IMER

Fuel - Engine Yanmar - Single-phase - 5.2 kW - Electric starter + Battery - AVR + Differential Kit - Compound voltage regulator - Large tank 15 L - Autonomy 9.45 h - 120 kg This model for residential areas or construction sites is distinguished by its compactness and robustness. Warranty 3 years

Price €3,238.50 Regular price €4,318.00 excluding VAT
€3,886.20 including tax
More