Sine Ultra Inverter 24V / 4000W - 230V - Mastervolt Converter
For the toughest tasks
Mass battery converters are designed for intensive professional use and semi-professional and sports environments. With a capacity of 4,000 W (AC) per unit, the Mass Sine Ultra can support the largest demand for energy. Since ten units can be used in parallel or 3x3 in configuration three-phasee, the Mass Sine Ultra can supply up to 40 kW.
The converter provides full power at 40 °C and works perfectly under extreme conditions such as those encountered in machine compartments and technical spaces. Like all products in the Mass range, this converter comes with a compact and robust housing. A converter that is the best choice if you are looking for AC range with a capacity greater than 3 kW.
Specificities
Output voltage: 230 V - 50 Hz
Rated battery voltage: 24 V
Minimum battery capacity: > 350 Ah
Continuous power at 40°C: 4000 W
Parallel use: yes up to 10 devices
Configuration three-phase possible, up to 3x3
Protection: IP23 - overheating, overload, short circuit, high/low voltage
Masterbus compatible
Dimensions: 472 x 318 x 178 mm
Weight 15 kg
Specifications
|
General specifications |
Output voltage (± 5 %) |
230 V - 50 Hz (± 0.01 Hz) |
Wave exit |
pure sinus |
Nominal battery voltage |
24 V |
Recommended battery capacity |
> 350 Ah |
Continuous power at 40 °C / 104 °F, cos phi 1 |
4000 W |
Crest power |
7000 W |
AC connection |
internal |
Galvanic insulation |
yes |
Performance |
> 92 % |
Parallel use |
yes, up to 10 devices |
Configuration three-phasee |
yes, up to 3x3 |
Display/indicator |
lED display |
Dimensions, HxlxP |
472 x 318 x 178 mm 18.6 x 12.5 x 7.0 inches |
Weight |
15 kg 33.1 pounds |
Standards |
EC, ABYC, E-mark |
|
Technical specifications |
Technology |
With HF cutting |
Low battery voltage, shutdown at |
19-22 V, dynamic window V |
Low battery voltage, starts at |
24 V, ± 0.5 V |
High battery voltage, shutdown at |
32 V, ± 0.5 V |
High battery voltage, starts at |
29 V, ± 0.5 V |
Maximum undulation on DC (battery) |
5% RMS |
Input intensity (nominal load) |
200 A |
Unladen power consumption (ON mode) |
660 mA – 16 W |
Power consumption (energy saving mode) |
300 mA – 7 W |
Minimal slow flow DC |
250 A |
Minimum cable section |
70 mm2 |
Typical harmonic distortion |
|
Cos phi |
all authorized power factors |
Switching system |
masterswitch and Systemswitch can be connected to all converters |
Temperature range (ambient temperature) |
-25 °C to 80 °C, decreasing > 40 °C -13 °F at 176 °F |
Cooling |
natural/forced |
Protection index |
IP23 |
Protection |
overheating, overload, short circuit, low/high battery voltage |
Compatible MasterBus |
yes |